HP服務(wù)器開機按F1或者F2維修,HP服務(wù)器開機報警維修,濟南HP服務(wù)器配件,濟南HP服務(wù)器維修
全國技術(shù)維修熱線:400-081-8101 13370510387 13969152522
qq:812469722 180415997 409630604 http://www.dellfw.com
開機出現(xiàn)F1和F2的提示通常都是由于Smart Array系列的陣列卡報警所致。
1. 1769-Slot X Drive Array - Drive(s) Disabled Due to Failure
During Capacity Expansion.Select F1 to continue with logical drives
disabled.Select F2 to accept data loss and to re-enable logical
drives.
故障原因:陣列加速器模塊被卸下或出現(xiàn)故障,擴展進程數(shù)據(jù)丟失;無法從陣列加速器中讀取擴展進程數(shù)據(jù);擴展因不可恢復(fù)的驅(qū)動器錯誤而終止;擴展因陣列加速器錯誤而終止。
解決方法:按F2鍵接受數(shù)據(jù)丟失并重新啟用邏輯驅(qū)動器;從備份里恢復(fù)數(shù)據(jù);如果是因驅(qū)動器質(zhì)量有問題或陣列加速器故障而導致的,請更換相應(yīng)的驅(qū)動器或陣列控制器。
2.1786-Slot 1 Drive Array Recovery Needed.Select F1 to continue
with recovery of data to drive.Select F2 to continue without
recovery of data to drive.
故障原因:系統(tǒng)處于臨時數(shù)據(jù)恢復(fù)模式下。先前出現(xiàn)故障或更換的驅(qū)動器尚未重建。
解決方法:按F1鍵啟動自動數(shù)據(jù)恢復(fù)程序,更換驅(qū)動器或驅(qū)動器工作時,數(shù)據(jù)自動恢復(fù)到驅(qū)動器X;按F2鍵使系統(tǒng)能夠以臨時數(shù)據(jù)恢復(fù)模式繼續(xù)運行。
3.1788-Slot X Drive Array Reports Incorrect Drive
Replacement.
故障原因:更換的驅(qū)動器被安裝在不正確的驅(qū)動器托架上;也可能因驅(qū)動器電源線連接有問題、數(shù)據(jù)電纜噪音或 SCSI
電纜有缺陷而顯示。
解決方法:按照指導重新正確的安裝驅(qū)動器;如果此消息是因電源線連接有問題而不是驅(qū)動器更換不正確所致,檢查電纜線路是否正確。
4. 1789-Slot X Drive Array SCSI Drive(s) Not
Responding......Check cables or replace the following SCSI drives:
SCSI Port Y: SCSI ID Z Select F1 to continue – drive array will
remain disabled. Select F2 to failed drives that are not responding
– Interim Recovery Mode will be enabled if configured for fault
tolerance.
關(guān)于我們 | 友情鏈接 | 網(wǎng)站地圖 | 聯(lián)系我們 | 最新產(chǎn)品
浙江民營企業(yè)網(wǎng) peada.cn 版權(quán)所有 2002-2010
浙ICP備11047537號-1